An overview
1, SYK series DC power supply is an adjustable, constant voltage, constant current switching power supply. This series of power supply with high precision, light weight, small size, beautiful appearance Fang, a long time at full load and so on.
2, This series of power is widely used in electronic production lines, laboratories, electroplating, battery charging, power communications equipment, maintenance, scientific research, production, education, and other units will use the device.
The nominal operating conditions:
1, input voltage: AC220V ± 10% 50Hz
2, the ambient temperature: -8 ° C-39 ° C
3, relative humidity:
4. MTBF: 50000H
storage conditions
1, ambient temperature: -20 ° C-80 ° C
2, relative humidity: less than 75%
Fourth, the technical parameters
1, the output voltage DC: nominal value continuously adjustable between 0
2, the output current DC: nominal value continuously adjustable between 0
3, the voltage stability: less than equal to 1%
4, voltage regulation rate: less than equal to 0.1%
5. Load regulation: less than equal to 1%
6, the ripple: less than 3% OUT PUT
Panel presentation A (see Figure 1), this panel application and (1800W) or less power.
Panel Introduction B see (Figure 2) between the power supply this panel application and (1800W-5000W)
(1) The current display
(2) Voltage Display
(3)Constant and protection indicator
(4) Working lights
(5) constant-current regulation
(6) The constant voltage regulation
(7) 20A of the following current output terminal
(8) Power switch
Panel presentation power between C see (Figure 3) Application of this panel (4000W- 9000W)
(1) The current display
(2) Voltage Display
(3) Operating indicator
(4) Constant and protection indicator
(5) voltage regulation
(6) constant current regulation
(7) 20A of the following current output terminal
(8) Power switch
A rear plate presentation see (Figure 4) Thereafter board applied (1800W) to The power
(1) 20A above. Current output terminal
(2) AC220V input port
See the rear panel presentation B (Fig. 5) Thereafter board applied (1800W- 5000W) between the power supply
(1) AC220V power input plug
(2) 20A over current output terminal
See rear panel presentation C (Fig. 6) Thereafter board applications and (4000W- 9000W) between the power supply
(1) AC220V power input connector
(2) 20A over current output terminal
SYK (series type and size table
Using the methods and precautions
1. Check before electrify: After switching the power supply is preceded checking storage and transport after transport if there is damage, such as loose screws, whether the abnormal appearance, before and after the power cord output terminals are falling and damp, etc., if the above situation promptly.
2. wiring: connect the ground wire and secure input and output power cord after confirming the connection is correct, only work after the joint firm.
3.no-load electricity: turn on the power switch, adjust the potentiometer constant pressure on the panel, then the voltmeter on the panel should be based on your adjusted and until you produce a corresponding change in the required voltage value.
4.adjust the output steady flow value: Ze press labeled panel connected between the output and the load connected to the wire, (note wire cross-sectional area should be large enough), and confirmed its constant after the load is connected firmly adjusted on the panel flow potentiometer to your desired steady flow value (note that only a small current circumstances it is possible to use this feature) General Keep constant potentiometer clockwise to maximum, otherwise it will cause the output power can not be loaded, because it makes in limiting state power.
5. the working environment: Do not use because Tun source load when work is people internally generated heat, if this time the outside temperature is too high will result in reduced efficiency of the power supply, and in severe ambient temperature higher than 39 degrees in the place even damaged or automatically shut down. (Recommended at room temperature)
6. Fan: fan of the power right then, please do not block the air inlet and outlet at work, you should leave enough space so that the heat of the fuselage. The machine fan with intelligent circuit control, only the internal chassis temperature exceeds 45 ° C fan will start their own, whereas less than 45 ° C will automatically stop.
7. Protection: input overvoltage, undervoltage, lightning, output overvoltage, overcurrent short circuit, overheating foregoing the opportunity to automatically turn on protection against equipment damage. In general protection status indicator will light green (note constant state of exception) will automatically cut off power serious.